High-Speed LWIR Science-Grade Camera

FLIR X6980 SLS™

Model: FLIR X6981 SLS (7.5–12 µm), f/2.5 Go to Product Support
product image

The FLIR X6980 SLS is an extraordinarily fast longwave IR camera designed for scientists and engineers who need to capture high-speed imagery for accurate thermal analysis and custom radiometric measurements. This thermal imaging camera combines 640 × 512 resolution from the SLS detector with the fastest high-speed frame rates to offer the shorter snapshot speeds and wider temperature bands needed to record crisp stop motion images of high-speed events. With a four-position motorized filter wheel and support for FLIR motorized focus lenses, the X6980 SLS will provide high quality recordings, save time, and mitigate frustration in dynamic acquisition environments.

Sales Contact Contact Sales

  • High Speed, High Sensitivity

    Capture full 640 × 512 imagery at up to 1004 Hz, with integration times that are 10x shorter than MWIR InSb cameras (ambient temperatures)

  • On-Camera RAM and SSD Recording

    Save up to 26,000 frames of data directly to on-camera memory or up to 15 minutes to included 512 GB SSD

  • Multiple Software Interfaces

    Stream thermal data directly to a computer to view, record, and analyze with FLIR Research Studio

Contact Sales

Want more information on this product?

Call +1 (866) 477-3687 to speak with a knowledgeable specialist.

Specifications
Resolution
640 × 512
Detector Pitch
25 µm
Spectral Range
7.5 µm (lower), 11.5–12.5 µm (upper)
Detector Type
Strained layer superlattice (SLS)
Camera f-number
f/2.5
Dynamic Range
14-bit
NETD
40 mK typical
Frame Rate [Full Window]
Programmable: 0.0015 Hz to 1004 Hz
Integration Time
Programmable: 270 ns to ~full frame
Standard Temperature Range [with band matched optics]
-20°C to 350°C (-4°F to 662°F)
Optional Temperature Range [with band matched optics]
ND1: 250°C–1500°C (482°F–2732°F) ND2: 500°C–3000°C (932°F–5432°F)
Filtering
4-Position motorized warm filter wheel, standard 1-inch filters, user swappable
Focus
Motorized (compatible w/manual)
Imaging & Optical
Available Lenses
Manual (7.5–12 µm): 17 mm, 25 mm, 50 mm, 100 mm, 200 mm Motorized (7.5–12 µm): 17 mm, 25 mm, 50 mm, 100 mm, 200 mm
Camera f-number
f/2.5
Close-up Lenses/Microscopes
1x
Detector Pitch
25 µm
Detector Type
Strained layer superlattice (SLS)
Digital Zoom
1x, Auto (best fit)
Direct to SSD Recording
Yes, removable 512 GB SSD included
Dynamic Range
14-bit
Filtering
4-Position motorized warm filter wheel, standard 1-inch filters, user swappable
Focus
Motorized (compatible w/manual)
Frame Rate [Full Window]
Programmable: 0.0015 Hz to 1004 Hz
Image Time Stamp
Internal IRIG-B decoder clock TSPI accurate time stamp
Integration Time
Programmable: 270 ns to ~full frame
Lens Interface
FLIR FPO-M (4-tab bayonet, motorized)
NETD
40 mK typical
On Camera Image Storage
RAM (volatile): 16 GB, up to 26,000 frames full frame SSD (user-removable/non-volatile): ~15 minutes of ~800 Hz recording with included 512 GB SSD (more than 2 hours possible with 4 TB SSD purchased separately)
Operability
99% typical
Overlay
Customizable (ability to toggle off)
Palette
Selectable 8-bit
Pixel Clock
355 MHz
Radiometric Data Streaming
Simultaneous Gigabit Ethernet (GigE Vision), Camera Link,CoaXPress® 1.1, dual 5 Gb links
Readout Modes
Asynchronous integrate while read, Asynchronous integrate then read
Readout Type
Snapshot
Resolution
640 × 512
Sensor Cooling
Closed cycle rotary
Spectral Range
7.5 µm (lower), 11.5–12.5 µm (upper)
Standard Video
HDMI, SDI
Subwindow Modes
Flexible windowing down to 32 × 4 (steps of 32 columns, 4 rows)
Video Modes
HD-SDI: 720p@50/59.9Hz, 1080p@25/29.97Hz; SD-SDI: 480i@60Hz, 576i@50Hz
Measurement & Analysis
Accuracy
≤100°C: ±2°C (±1°C typical), >100°C: ±2% of reading (±1% typical)
Ambient Drift Compensation [with factory cal]
Yes
Automatic Gain Control
Manual, Linear, Plateau equalization, ROI, DDE
Optional Temperature Range [with band matched optics]
ND1: 250°C–1500°C (482°F–2732°F) ND2: 500°C–3000°C (932°F–5432°F)
Standard Temperature Range [with band matched optics]
-20°C to 350°C (-4°F to 662°F)
Communication & Data Storage
Synchronization Modes
Sync In, Sync Out, Tri-Level Sync
Power
Power
24 VDC (<50 W steady state)
Environmental & Certifications
Mounting
2 × 1/4 in. –20 / 1 × 3/8 in. –16 / 4 × #10 –24 / Side: 3x 1/4 in. –20 (each side)
Operating Temperature Range
-20°C to 50°C (-4°F to 122°F)
Media gallery
Connecting to your FLIR X-Series High-Speed, High Definition Camera
Connecting to your FLIR X-Series High-Speed, High Definition Camera
Installing warm filters on FLIR cooled science cameras
Installing warm filters - SCI cameras
Unboxing your FLIR X-Series High-Speed, High Definition Camera
Unboxing your FLIR X-Series High-Speed, High Definition Camera
Related Documents

FLIR X6980 SLS™ - Model: FLIR X6981 SLS (7.5–12 µm), f/2.5

Change Selection