The FLIR EM54 is ideal for inspecting and troubleshooting HVAC/R ducting systems within residential, commercial, and industrial facilities. This meter can help you verify that duct inlets and outlets have the specified volumetric flow – a prerequisite to an efficient functional system. Featuring humidity, wet bulb, and dew point functions, the EM54 can measure deviations from proper relative humidity levels. Plus, the included Type-K contact temperature probe is useful to check electric motors and thermal equipment components for proper operating temperatures.
- Products
- Test & Measurement
- HVAC & Air Quality
- Environmental Meters
- FLIR EM54
Added to cart
-
ACCURATE AND RELIABLE
Receive high-quality data consistently, and work without interruption. Using the tripod, place the meter away from objects that may influence relative humidity measurements.
-
INSPECT AND TROUBLESHOOT EFFICIENTLY
Work on a wide range of systems more efficiently using the contact temperature probe and wet bulb/dew point calculations.
-
EASY TO USE
Intuitively operate this simple, ergonomic meter with a backlit display, a ‘hold’ function that freezes readings, and well-marked function keys.
Contact Sales
Want more information on this product?
Call +1 (866) 477-3687 to speak with a knowledgeable specialist.
Specifications
- Air Velocity (Vane Anemometer Probe)
- 0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots
- Air Flow
- 0 to 999900 CMM (0 to 999900 CFM)
- Air Temperature
- 10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)
- Relative Humidity
- 5% to 98% ±3.5%
- Dew Point
- -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)
- Wet Bulb (Calculated)
- -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)
Measurement & Analysis
- Air Temperature
- 10 to 30°C (50 to 86°F), ±1°C (1.8°F); -30 to 9.9°C (-22 to 50°F) and 31 to 60°C (88 to 140°F), ±2°C (3.6°F)
- Air Velocity (Vane Anemometer Probe)
- 0.4 to 30 m/s, ±3% +0.2 m/s ; 79 to 5906 ft/min, ±3% +40 ft/min; 1.4 to 108 km/h, ±3% +0.8 km/h; 0.9 to 67.2 mph, ±3% +0.4 mph; 0.8 to 58.3 knots, ±3% +0.4 knots
- Contact Temperature Type K thermocouple
- -99.9 to 99.9°C (-148 to 212°F), ±1.5% +1°C (1.8°F); 100 to 1372°C (212 to 2502°F), ±1.5% +2°C (3.6°F)
- Dew Point
- -30 to 60°C (-22 to 140°F), ±3°C (4.8°F)
- Relative Humidity
- 5% to 98% ±3.5%
- Wet Bulb (Calculated)
- -30 to 50°C (-22 to 122°F), ±3°C (4.8°F)
Imaging & Optical
- Display Type
- Backlit, multifunction LCD
Power
- Auto Power Off (APO)
- Configurable from 5 to 60 min in 8 increments
- Battery Life
- 120 hours typical
- Battery status indicator
- Low battery indication
- Battery Type
- 1x 9 V
General
- Air Flow
- 0 to 999900 CMM (0 to 999900 CFM)
- Anemometer Body Length
- 150 mm (5.9 in)
- Anemometer Cable Length
- 950 mm (37.4 in)
- Anemometer Vane Diameter
- 70 mm (2.8 in)
- Dimensions (L x W x H)
- 275 × 65 × 45 mm (10.8 × 2.6 × 1.8 in)
- Housing material
- Impact-resistant plastic
- Includes
- Vane anemometer probe, Type-K thermocouple probe, soft carrying pouch, 9 V battery, tripod mount
- Weight
- 283.9 g (10 oz) with battery installed, no external probes
Environmental & Certifications
- Certifications
- CE, RCM
- Drop test
- 1 m (3.3 ft), not including removeable probes
- Operating Temperature
- 0 to 50°C (32 to 122°F)
- Storage Temperature Range
- -10 to 60°C (14 to 140°F)
- Warranty
- Limited 3 years
Related Documents
Returns and Shipping Information for Orders Placed on FLIR Websites
Orders placed through FLIR.com will ship via free 2-day expedited service to the contiguous 48 states.
Returns
We offer a 30-day return policy on all products, no questions asked. Your order confirmation will contain instructions on how to contact our Customer Care team to initiate the return.
shipping time cut-offs
Orders placed Monday-Friday before 12:00 PM (noon) EST will likely ship the same day. All other orders will ship the next business day.
Want more information on this product?
Call +1 (866) 477-3687 to speak with a knowledgeable specialist.